News & Case Studies

Fire Safety for Retail Stores and Shopping Centre’s in Australia

Retail stores and shopping centres present a fire safety environment that is unlike most other commercial buildings. High visitor numbers, constant stock movement, multiple tenancies with different risk profiles, food court kitchens, electrical rooms, loading docks, and layouts that change as tenancies are renovated or subdivided all create a dynamic compliance picture that requires active management.

For retail building owners, centre managers, and individual store operators, understanding your fire safety obligations under the National Construction Code and AS 1851 is essential. This guide covers the key requirements for retail stores and shopping centres in Australia, from essential services and extinguisher placement through to AFSS compliance and the specific challenges of managing fire safety across a multi-tenancy retail environment.


Managing fire safety compliance for a retail building or shopping centre? Fire Safe ANZ provides essential services maintenance and AFSS support for retail properties across Australia. Request a quote today


Class 6: Retail Buildings Under the NCC

Retail stores and shopping centres are classified as Class 6 buildings under the National Construction Code, defined as a shop or other building for the sale of goods by retail or the supply of services direct to the public. This includes supermarkets, department stores, specialty retailers, and shopping centres of any size.

Class 6 buildings must meet the NCC’s fire safety provisions, which scale with building size, height, and floor area. Larger retail buildings and shopping centres face more demanding requirements than small standalone shops, including:

  • Automatic fire sprinkler systems in most large retail buildings and all shopping centres above a threshold floor area
  • Smoke hazard management systems in buildings with atriums or large open floor plates
  • Fire control rooms in larger centres where a centralised emergency response capability is required
  • Enhanced compartmentation requirements in multi-storey retail buildings

The specific requirements that apply to your building are set out in your fire safety schedule, which is the document that drives your essential services maintenance program and your AFSS obligations.


Essential Fire Safety Measures in Retail Buildings

Depending on the building’s fire safety schedule, classification, and size, essential fire safety measures in a retail building typically include:

  • Smoke detection and fire alarm systems, including Fire Indicator Panels (FIPs)
  • Fire sprinkler systems throughout the building
  • Fire hydrant and hose reel systems
  • Fire extinguishers, placed and maintained in accordance with AS 2444
  • Emergency lighting and exit signs
  • Emergency Warning and Intercommunication Systems (EWIS) in larger centres
  • Fire doors and smoke doors throughout the tenancy and common areas
  • Smoke hazard management systems where installed
  • Passive fire protection including fire-rated walls, penetration seals, and fire dampers

Each of these systems must be maintained at the correct AS 1851 frequency and documented in the building’s maintenance logbook. All records must be retained on site for a minimum of seven years.

For a full breakdown of what AS 1851 requires, read: What Is AS 1851? A Guide for Building Owners


Extinguisher Placement in Retail Environments

Correct fire extinguisher placement in a retail store or shopping centre is more complex than in a standard office or warehouse. Retail environments include multiple fire risk zones within a single building, each potentially requiring a different extinguisher type:

  • Sales floors and stockrooms: ABE dry chemical extinguishers are standard
  • Food courts, cafes, and takeaway outlets with cooking equipment: wet chemical extinguishers are required at cooking stations, CO2 near electrical equipment
  • Electrical rooms and data infrastructure: CO2 extinguishers to avoid powder residue damage
  • Loading docks and storage areas: ABE extinguishers sized for the storage volume and risk

A key compliance issue in retail is that extinguishers must remain visible, accessible, and correctly signposted at all times. Retail displays, advertising structures, delivery cages, and merchandising fixtures frequently obstruct extinguishers over time. This is one of the most common deficiencies identified during retail fire safety audits.

For a full guide to extinguisher types and placement requirements, read: Fire Extinguisher Types Australia


Fire Hose Reels: Layout Changes Create Compliance Gaps

Fire hose reels in retail buildings must provide coverage across the required floor area. In a shopping centre, this coverage calculation must be reassessed whenever a tenancy is reconfigured, subdivided, or expanded, because a hose reel that adequately covered a large open tenancy may no longer cover the same area once it has been divided by new walls.

This is a compliance gap that accumulates silently in many retail buildings as tenancies change hands and fit-outs are completed without fire safety coverage being reviewed. If your building has undergone significant tenancy changes since the fire safety schedule was last updated, it is worth confirming that hose reel coverage still meets the required standard.


Fire Doors and Evacuation Routes in Retail

Retail environments create specific challenges for fire door and evacuation route compliance. Stock, delivery cages, boxes, and equipment are frequently placed near fire doors or along evacuation routes. A fire door that is propped open to allow stock movement between areas is not providing the passive fire protection it was installed to deliver.

Common fire door compliance failures in retail buildings include:

  • Doors propped open permanently with wedges or stock
  • Self-closing mechanisms disabled or degraded
  • Non-compliant hardware installed during tenancy fit-outs without fire safety sign-off
  • Missing or illegible compliance tags on fire-rated doors
  • Exit routes obstructed by displays or seasonal merchandising

Any of these issues will be identified during an AFSS assessment and must be rectified before the statement can be endorsed. Read our full guide: Fire Door Compliance Tags: What Building Owners Need to Know


Retail tenancy fit-outs and layout changes can create silent compliance gaps. Fire Safe ANZ can assess your building and identify any fire safety deficiencies before your next AFSS. Get in touch


Multi-Tenancy Responsibility: Who Is Responsible for What?

In a multi-tenancy retail building or shopping centre, fire safety responsibility is divided between the building owner or centre manager and individual tenants. Getting this division clearly established in leases and management agreements is essential.

Building owner or centre manager responsibilities:

  • All base building fire safety systems including sprinklers, hydrant and hose reel systems in common areas, FIP and alarm systems, emergency lighting in common areas, and fire doors in common corridors and mall areas
  • Lodging the Annual Fire Safety Statement with council
  • Maintaining AS 1851 compliant maintenance records for all base building systems

Individual tenant responsibilities:

  • Fire safety measures within the tenancy, including extinguishers, hose reels, and wet chemical suppression systems in food tenancies
  • Ensuring that tenancy fit-outs do not compromise base building fire safety systems, including sprinkler head clearances, detector coverage, and fire door integrity
  • Keeping egress paths within the tenancy clear at all times

Retail chains operating stores in multiple centres must maintain compliance across every location. As one industry guide notes, retail chains that occupy space in multiple centres require an understanding of fire safety regulations for each location in order to maintain mandatory compliance. This is where a structured multi-site program becomes essential.

For more on managing fire safety across multiple sites, read: Fire Safety for Facilities Managers: How to Stay Compliant Across Multiple Sites


Sprinkler Head Clearances: A Retail-Specific Risk

Sprinkler systems in retail buildings can be compromised by stock stacking that exceeds the clearance requirement between the sprinkler heads and the top of stored goods. Most sprinkler standards require a minimum clearance of 450mm to 500mm between the deflector plate of each sprinkler head and any material stored beneath it.

In a busy retail stockroom or warehouse storage area, this clearance is frequently lost as stock levels rise during peak periods. A sprinkler head that is obstructed by stock cannot distribute water correctly in the event of a fire, potentially failing to suppress a fire that it was designed to control.

Building owners and store managers should include sprinkler head clearance as a regular visual check, not just an annual inspection item.


AFSS Obligations for Retail Buildings

If your retail building has a fire safety schedule, you are required to lodge an Annual Fire Safety Statement with your local council every 12 months. From 13 February 2026, the AFSS cannot be endorsed unless maintenance records demonstrate compliance with AS 1851’s prescribed service frequencies across every essential fire safety measure on the schedule.

For a full breakdown of the AFSS process, read:


Fire Safe ANZ: Retail Fire Safety Compliance

Fire Safe ANZ provides comprehensive fire safety compliance services for retail stores, shopping centres, and multi-tenancy retail buildings across NSW, Queensland, Victoria, Western Australia, and beyond. Our services include:


Keep your retail building compliant and your customers and staff protected. Call 1300 553 566 or request a quote online


Related Reading

Get In Touch Today

Proud member of

© Fire Safe ANZ. All rights reserved.